The Paintlab+ Viscomixer is a versatile instrument used to measure the change in viscosity during the addition of a solvent or thinner.
If you need discussion about this product, please click “Find Solution”. Or click the “Order Now” to buy now.
Viscosity measurement of coatings is essential at each stage of the manufacturing process to ensure consistent quality standards. Many parameters can affect the rheological behaviour of a finished coating resulting in undesirable effects such as inconsistent performance, poor levelling or sagging.
The use of high precision measuring instruments is therefore essential in quality control to prevent such problems occurring during formulation, manufacture and application.
The Paintlab+ Viscomixer is a versatile instrument used to measure the change in viscosity during the addition of a solvent or thinner.
Three Viscomixer models are available each offering a different measuring range according to the viscosity of the test sample. A sample from a production batch can be quickly and easily measured in a 250ml tin and the required thinning ratio determined for scaling into the production process. The instrument operates at a fixed speed of 562rpm to directly measure the viscosity in Poise (P).
Features
Precise Measurement
High stability motor speed control ensures accuracy and repeatabilty during each test.
Real-time high resolution graphing allows monitoring of changes during measurement providing identification of inconsistencies between samples.
Measurement results are displayed instantly on screen after test in all three units.
Advanced temperature monitoring
An integrated temperature probe accurately measures and records sample temperature for each test. As sample viscosity is influenced by test temperature, accurate monitoring and recording ensures reliability of test results.
Automatic Operation
Fully automated operation saves time by accurately lowering the paddle into the sample to the correct height for a number of standard container sizes. Once the test has completed the paddle automatically raises to drain off, saving time during cleaning. The easy to use quick release magnetic paddle holder allows rapid removal for cleaning after use.
Paint Resistant Design
Lab-tough glass allows easy removal and cleaning of unintentional splashes and smears from the capacitive sense buttons and screen.
The solvent resistant anodised aluminium instrument chassis ensures the instrument can be cleaned and restored to pristine condition even in the toughest working environments.
Data transfer
Measurement data including time, date and test temperature can be printed to a Rhopoint label printer (supplied as an optional accessory).
Printed labels can be attached to each sample for easy identification and recording of results.
Flexible range configuration
The Viscomixer can be configured for any of the three ranges by purchasing an additional paddle for the range required along with a calibration oil kit.
Full details of paddles available along with their respective calibration kits are detailed at the back of the brochure.
Calibration
Annual calibration can be performed remotely by the user using the Rhopoint certified recalibration kit. Step by step instructions and automatic verification ensure accurate, traceable results.
RANGE | 0.1 – 15 P |
0.1 – 65 P | |
1.0 – 340 P * | |
RESOLUTION | 0.1 P (1.0 P*) |
ACCURACY | +/- 2% |
REPEATABILITY | +/- 1% |
SPEED | 562 rpm +/- 0.1% |
CONTAINER SIZES | 250ml |
OPERATING TEMPERATURE | 15° C to 35° C |
POWER | 90-240V AC – 50/60 Hz |
WEIGHT | 7.25 kg |
SIZE | (H) 460 x (W) 320 x (D) 190 mm |
PACKED WEIGHT | 10 kg |
COMMODITY CODE | 9027 8017 |
The Novo-Gloss 20/60/85° gloss meter is designed to meet the measurement criteria for most gloss measuring applications.
The Novo-Gloss Trio low cost glossmeter is ideal for gloss measurements of all surfaces and is suitable for matt to mirror gloss surfaces
The Novo-Gloss 60 degree gloss meter is suitable for measuring gloss in most applications from matt to high gloss finishes.
The Novo-Gloss Dualgloss gloss-meter is perfect for basic gloss measurement and is best suited for mid to mirror gloss surfaces (10+ GU @60°)
Designed specifically to measure the gloss of surfaces that cannot be measured using traditional gloss-meters, the Novo-Gloss Flex 60 gloss-meter combines the functionality and reporting of an advanced gloss-meter with an ultra lightweight remote measuring head.
The Novo-Curve glossmeter is a unique instrument with specially designed optics for accurately measuring curved surfaces and small areas. It can also be used to measure flat surfaces and areas which are too small to measure with standard glossmeters.
The Novo-Gloss 20/60/75ºS gloss meter is a fully featured instrument measuring the gloss of surfaces.
The Rhopoint Novo-Gloss Lite 45º measures gloss using a specialist geometry often specified in the ceramics, metal manufacturing and film making industries.
The Rhopoint IQ quantifies surface quality problems that are invisible to a standard glossmeter and profiles how light is reflected from a surface.
The Rhopoint IQ Gloss Haze & DOI Meter quantifies surface quality problems that are invisible to a standard glossmeter and profiles how light is reflected from a surface.
The Rhopoint IQ Flex 20 quantifies surface quality problems such as orange and peel and haze that are invisible to a standard glossmeter and profiles how light is reflected from a surface.
The Rhopoint IQ-S was specially designed and built to match automotive interior gloss measurement standards. IQ-S gloss measurements are fully compatible with existing Micro-TRI-gloss-S results.
The Rhopoint IQ Concrete Clarity Meter measures reflected image quality; it is the only hand held instrument that profiles how light is reflected from a surface. Glossmeters are usually used to measure the “shininess” of a surface but are not sensitive to common effects which reduce appearance quality.
Measures the minimum film forming temperature of water based coatings. Determines the MFFT of latex, emulsions and adhesives -10°C to 60°C operation
Measures the minimum film forming temperature of water based coatings. Determines the MFFT of latex, emulsions and adhesives -10°C to 90°C operation
Required when the temperature of the water supply to the instrument is >20ºC higher than the target temperature at the cold end of the
selected range.
The PAINTLAB+ Krebs Viscometer from Rhopoint Instruments offers high accuracy viscosity measurement with advanced functionality.
This Viscometer is specifically designed to provide stringent testing conditions to allow the measurement of these materials as the viscosity changes according to the shear stress that is applied.
The Paintlab+ Viscomixer is a versatile instrument used to measure the change in viscosity during the addition of a solvent or thinner.