Performance that matters LA-960
- Measure particle size between 10 nanometers and 5 millimeters
- State of the art nanoparticle measurement resolves peaks at 30 nanometers
- Suitable for suspensions, emulsions, powders, pastes, gels, and creams
- Easy to use dry powder accessory, read the PowderJet page for more information
- Requires only micrograms* of sample, minimizing cost of analysis
- Flexible, fully automated measurement sequences maximize precision and method compliance
- Excellent reproducibility and unit-to-unit agreement, read the Gage R&R Study for more information
- Measurements in less than 60 seconds boost productivity
- Based on the ultra-durable LA-950 platform, noted for its reliability
Watch Video Overview LA-960 Product
Software that grows to meet your needs
- New users are guided by the Method Expert software to create powerful measurement methods with no prior training
- Experienced users create turn-key measurements with the Sequence function to include custom messages, measurement averaging, pass/fail repeats, and much more
- Advanced users benefit the Intensity Graph, Custom Calculations, and other power tools to deeply understand their measurements
- The brand new user interface emphasizes ease of use to ensure hassle-free operation
- Integrated 21 CFR Part 11 compliant software available with user administration, audit trail, and electronic signature functionality
HORIBA’s performance guarantee
- Guaranteed accuracy of ± 0.6%**
- Excellent unit-to-unit precision, ideal for multi-location requirements
- ISO 13320:2009 compliant
- IQ/OQ available
- LA-960 performance verified on every unit with NIST-traceable mono- and polydisperse size standards
Our particle expertise = your solution
HORIBA’s experienced staff of technical and applications specialists support the LA-960 in 54 offices across 45 countries. We are committed to the satisfaction of our users and to the education of the greater industry and provide many channels of support including:
- Sample analysis via the many Applications Labs around the world
- Free software updates, webinars, technical notes, and much more in the Download Center
- Instant support via phone, e-mail, and online meeting
- On-site and in-house user training courses
- Service contracts, verifications, and validations to fit every requirement
- Advanced software tools to correlate data from other particle size analyzers to maintain historic specifications
Measurement Method | Mie Scattering Theory |
Measurement Range | 0.01 μm to 5000 μm |
Measurement Time | 1 minute from dispersion liquid filling to measurement and rinse. |
Sampling System | Required Sample Amount:Sample 10 mg to 5 g (Depends on sample material) |
Dispersion Medium:Approx. 180 mL to 250 mL (Using Flow Cell) | |
Viscosity:Less than 10 mPa・s | |
Optical System | Light Source:650 nm Laser Diode approx. 5.0 mW |
405 nm Light Emitting Diode (LED) approx. 3.0 mW | |
Detectors:Silicon Photo Diode | |
Circulation System | Ultrasonic Probe:Frequency 20 kHz 7-Level selections |
Circulation Pump:15-Level selections | |
Agitator:15-Level selections | |
Flow/Fraction Cell:Tempax Glass | |
Power Supply | 120 V AC ±10% or 230 V AC ±10%, 50/60 Hz ±1% |
Power Consumption | 300 VA |
Operating Temperature | 15 to 35℃ (59 to 95℉) |
Operating Humidity | Relative Humidity 85% or less (no condensation) |
External Dimensions | 705 x 565 x 500 mm (28 x 23 x 20 in) |
(W x D x H:not including dimensions of projections) | |
Mass Approx | 56 kg (123 lb) |
The new MacroRAM™ Raman spectrometer brings simplicity to Raman measurements without compromising the ability to handle even the most complex samples. Its compact and robust design, including Class 1* laser safety means it’s safe for use in most environments, from undergraduate teaching labs to industrial QC applications.
This latest evolution in the LA series advances scientific knowledge for tomorrow’s world through intuitive software, unique accessories, and high performance. The LA-960 continues HORIBA’s proud tradition of leading the industry with innovative design.
Aqualog® is the only instrument to simultaneously measure both absorbance spectra and fluorescence Excitation-Emission Matrices. EEMs are acquired up to a 100 times faster than with other instruments. A better, faster and economical method for monitoring organics.
Ultra fast compact spectrofluorometer for analytical molecular fingerprinting
From the global leaders in fluorescence comes a new bench-top instrument and a new concept for analytical molecular spectroscopy.
The FluoroMax® series represents Horiba’s industry-leading fluorometer performance in a convenient, affordable, easy-to-use benchtop model. The FluoroMax® family, with its unique all reflective optics and photon counting was the first to bring the sensitivity of a modular fluorometer to a tabletop fluorescence instrument.