The Computrac MAX 5000XL moisture, solids and ash analyzer can provide accurate readings for both moisture and ash from a single sample, offering many of the same features of thermogravimetric analyzers at a fraction of the cost. With a maximum temperature of 600°C and a maximum sample size of 100 grams, the MAX 5000XL has the versatility to a wide range of material testing tasks.
If you need discussion about this product, please click “Find Solution”. Or click the “Order Now” to buy now.
Features Computrac® MAX® 5000XL
High Temperature Testing: The heater of the Computrac® MAX® 5000XL can reach temperatures as high as 600ºC, giving it the ability to perform both loss on drying (LOD) and loss on ignition (LOI) testing and making it an ideal alternative to expensive, thermogravimetric analyzers.
Rugged Construction: Equipped with a ruggedly designed metal casing and a high temperature heater, the MAX 5000XL is designed to provide lab quality data whether it is in the lab or on the production floor.
Versatile: The MAX 5000XL is able to test material up to 100 times faster than standard reference methods and is ideal for everything from plastics and pharmaceuticals to foods, biomass materials and more.
Flexible Ending Criteria: User adjustable ending criteria help to optimize test results and performance for your unique application or material.
Real-Time Results: The MAX 5000XL offers simple, menu-driven operation and a user programmable interface with a keypad and large color display that allows users to view real-time moisture curve and rate of moisture loss graphs during testing.
Multistage Testing: Several tests can be linked in order to form a single, multistage test that can change temperatures, ending criteria and times between each test segment. This allows the instrument to test for moisture, solids and ash content with a single sample.
Self-Cleaning Oven: The oven of the MAX 5000XL features a self-cleaning cycle that simplifies routine maintenance. It runs for 45 minutes at 550ºC.
Web Server: The optional web server allows users to monitor tests remotely and check in with operators. It also lets users download results and calibration reports, view the audit log and transfer programs between instruments.
Versatile
Get an accurate readings for both ash and moisture content from a single sample.
Fast
Moisture and ash readings in half an hour or less.
Simple
One-button operation with no intermediate weighing or cooling steps required.
Durable
Made in the USA with an all-steel enclosure, the MAX 5000XL was designed for heavy duty use.
Accurate
Correlates to popular methods, including ASTM D5630, ASTM D4574, ASTM E1534 and more.
ASTM & Regulatory Compliance
21 CFR Part 11 Compliant (optional): Meet regulatory compliance standards for pharmaceutical and medical device companies
ASTM D6980-12: Standard Test Method for Determination of Moisture in Plastics by Loss in Weight (MAX® 4000XL and MAX® 5000XL)
ASTM D7232-06: Standard Test Method for Rapid Determination of the Nonvolatile Content of Coatings by Loss in Weight (MAX® 4000XL and MAX® 5000XL)
ASTM C471M-16: Standard Test Methods for Chemical Analysis of Gypsum and Gypsum Products (Metric)
It also correlates well with popular methods, including: ASTM D5630, ASTM D4574, ASTM E1534, and more.
Moisture | Solids Range | 0.1% to 99.9% |
Ash | LOI Range | 0.5% to 100% |
Moisture Resolution | 0.0001% |
Balance Resolution | 0.0001 g |
Moisture Repeatability | <5% RSD for samples >10% moisture |
Ash Repeatability | ≤5% RSD for samples >10% ash |
Temperature Range | 25°C to 600°C |
Heating Element | Ceramic |
Sample Size | 100 mg to 100 g |
Results | Moisture, Solids, Dry Weight, Ash, LOI |
Ending Criteria | User adjustable: Prediction, Rate, Time, Reliability and 4 other combinations |
Memory | Stores up to 250 programs, last 1000 test |
results and last 100 graphs | |
Statistical Analysis | Mean, SD, RSD |
Balance Calibration | Menu driven calibration by the end user; |
NIST traceable calibration performed by the manufacturer | |
Heater Calibration | Menu driven, NIST traceable calibration by the end user with optional |
Temperature Calibration Kit | |
Operating Environment | 0-35 ºC at <50% RH; |
0-30 ºC at <80% RH | |
Power Requirements | 100-120 VAC, 50/60 Hz, 8A or |
220-240 VAC, 50/60 Hz, 4A | |
Dimensions | 18.5” L x 12.7” W x 9.5” H |
(47 cm L x 32.3 cm W x 24 cm H) | |
Weight | 31 lbs. (14 kg) |
Warranty | Two years, factory parts and labor (one year international) |
Rear Panel Connections | Ethernet, serial port, parallel port |
Display | 1/4 VGA, 320 x 240 pixel, color |
Certifications | UL, CE |
FCC Part 15, Class A Tested to standards EN55022, | |
EN 90101-1 Temperature Calibration Interface certified for use | |
with the MAX® 5000XL |
The VPXL is ideal for nearly any application in which Karl Fischer titration is used. It features an upgraded heater and increased control over testing temperatures. The VPXL is also compatible with multiple sizes of sample vials and is equipped with stepped temperature testing capabilities for enhanced method development.
The Computrac MAX® 4000XL provides quick, reliable and accurate results. This improves the ability to adjust or monitor processes, ensuring quality products while minimizing waste, energy requirements and man-hours. Ease of use and durability, along with superior service and support make the Computrac® MAX® 4000XL an ideal choice for research, manufacturing and laboratory environments.
The Computrac MAX 5000XL moisture, solids and ash analyzer can provide accurate readings for both moisture and ash from a single sample, offering many of the same features of thermogravimetric analyzers at a fraction of the cost. With a maximum temperature of 600°C and a maximum sample size of 100 grams, the MAX 5000XL has the versatility to a wide range of material testing tasks.
The Jerome® J505 Mercury Vapor Analyzer is a portable fluorescence spectroscopy analyzer, which allows the detection cell to be simpler, smaller, lighter weight and more durable than competing spectroscopy instruments. The highly efficient optical cell requires less flow to purge the system, allowing the J505 to run at a lower flow rate minimizing sample dilution as found in competing spectroscopy instruments.
The Jerome® J405 portable mercury vapor monitor is redefining the portable mercury vapor analyzer market. Significant performance enhancements and modern communications capabilities have been combined to create a new option for mercury spill detection and clean-up analysis. The J405 utilizes the industry-proven, inherently stable and reliable gold film sensor technology and simple, one-button operation. The ergonomically-designed handle, lighter exterior case and significantly lower detection capabilities (0.5 µg/m3) make it a portable, easy to use, low-level mercury detection instrument.
The Jerome® 431-X mercury vapor analyzer uses our proprietary gold film sensor for accurate detection and measurement of toxic mercury concerns for applications such as industrial hygiene monitoring, mercury spill clean up and mercury exclusion testing. Simple push-button operation allows users to measure mercury levels from 0.003 to 0.999 mg/m3 in just seconds.