Deuterium Lamps (D2)

Applications – UV-Visible Spectroscopty, Spectrofluorimetry UV detectors attached to HPLC instruments, Colorimetry, Refractometry and as a non-atomic source for background correction in Atomic Absorbtion Spectroscopy.

If you need discussion about this product, please click “Find Solution”. Or click the “Order Now” to buy now.

Applications

UV-Visible Spectroscopty, Spectrofluorimetry UV detectors attached to HPLC instruments, Colorimetry, Refractometry and as a non-atomic source for background correction in Atomic Absorbtion Spectroscopy.

Range

A number of configurations are available including different filament voltages, terminal connectors, aperture sizes and brackets to suit many different instruments.

Warranty:

  1. Do not subject the lamp to mechanical shock.
  2. Before using the lamp, ensure glass envelope is clean and free from dirt. Envelope may be gently wiped with either alcohol or acetone. 
    Caution: the circumference of the glass envelope around the light box is very thin and should be handled with extreme care.
  3. Care must be taken not to touch lamp body with bare hand, as it’s temperature reaches over 200°C during operation.
  4. UV radiation is harmful to eyes. Suitable eye protection must be worn when observing light output.
  5. Since this lamp operates at high voltages, extreme caution is require to prevent electrical shock.
No. ProductInstrumentElectrical
Filament / Heater VoltageFilament / Heater CurrentDischarge / Arc VoltageDischarge / Arc CurrentLeadsTerminals
StartOperatingStrikeOperatingBlackRedGreen
P700Various10 VDC5 – 7 VDC1.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnodeTinned Copper Wire
P701GBC Scientific10 VDC5 – 7 VDC1.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnode3 Pin Housing
P702GBC Scientific10 VDC5 – 7 VDC1.5A Max@25°C >350 VDC60 – 90 VDC10 -300mA  Octal connector
P703Perkin Elmer/Hitachi / Merck/Hitachi / Hitachi10 VDC5 – 7 VDC1.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnodeSpade Terminals
P704Altec / Beckman / Biorad / Dupont / Erma / Hitachi / Jasco / Unicam / Varian10 VDC5 – 7 VDC1.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnodeSpade Terminals
P705Aktec / Beckman / Biorad / Joyce Loebl / Kontron LDC / Varian / Waters / Saitron / Spectra Physics / Turner2.5 – 3.0 VDC1.5 – 2.04.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnodeSpade Terminal
P706Varian10 VDC5 – 7 VDC1.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnode3 Pin housing
P712Perkin Elmer10 VDC5 – 7 VDC1.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnode3 Pin housing
P713AAltex / Barspec / Beckman / Biorad / Cecil Instruments / Coleman10 VDC5 – 7 VDC1.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnodeSpade Terminal
Dupont / Gilford / Hitachi / Perkin Elmer / Pharacia / Perkin Elmer
P714Spectra Physics2.5 – 3.0 VDC1.5 – 2.04.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnode3 Pin housing
P715Varian10 VDC5 – 7 VDC1.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnode4 Way housing
P716Waters2.5 – 3.0 VDC1.5 – 2.04.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnodeSpade Terminal
P716AWaters 486 & Waters 486LC2.5 – 3.0 VDC1.5 – 2.04.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnode3-Pin Housing
P717Bas / GBC Scientific10 VDC5 – 7 VDC1.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnode3-Pin Housing
P718Perkin Elmer10 VDC5 – 7 VDC1.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnode3-Pin Housing
P719Shimazdu AA-670, AA-670G, AA-6200, AA-6300, AA-6500, AA-6800, CS-920, CS-930, CS-9002.5 – 3.0 VDC1.5 – 2.04.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAOctal Connector
P721Agilent (Hewett Packard)2.5 – 3.0 VDC1.5 – 2.04.5A Max@25°C >350 VDC60 – 90 VDC10 -300mA3 Pin housing
P726Jasco 78002.5 – 3.0 VDC1.5 – 2.04.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAOctal Connector
P729Perkin Elmer10 VDC5 – 7 VDC1.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnodeCanSpade Terminals
P733Waters – 9962.5 – 3.0 VDC1.5 – 2.04.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnode3 Pin housing
P735Perkin Elmer 4100, 2100, 1100(B) and Aanalyst 600/700/800 AA Spectrometers2.5 – 3.0 VDC1.5 – 2.04.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnode3 Pin housing
P736Thermo Fisher: Helios & Aquamate range10 VDC5 – 7 VDC1.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnode3 Pin housing
P737Thermo- Fisher , Solar S42.5 – 3.0 VDC1.5 – 2.04.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnodeCan4 Way Housing
P738Thermo- Fisher, Solar M5,M62.5 – 3.0 VDC1.5 – 2.04.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnodeCan4 Way Housing
P739Thermo- Fisher, Solar 9292.5 – 3.0 VDC1.5 – 2.04.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnodeCan4 Way Housing
P748Perkin Elmer AAnalyst 200/4002.5 – 3.0 VDC1.5 – 2.04.5A Max@25°C >350 VDC60 – 90 VDC10 -300mAFilament & CathodeAnodeCan3-Pin housing
No. ProductOptical
Window materialSource apertureWavelength RangeNoiseDrift
P700UV Transmitting Borosilicate (Quartz is optional – P701Q)Ø1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P701UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P702UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units

P703

UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P704UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P705UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P706UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P712UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P713AUV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P714UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P715UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P716UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P716AUV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P717UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P718UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P719UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P721UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P726UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P729UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P733UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P735UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P736UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P737UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P738UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P739UV Transmitting BorosilicateØ1mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units
P748UV Transmitting BorosilicateØ0.5mm Diameter185nm – 400nm<1 x 10-4 Absorption units< 3 x 10-3 Absorption units

Photron’s P800 Series for all AAS compatible with 37mm or 1.5″ base 2 Pin Octal Base Hollow Cathode Lamps including AAS Instruments by Varian, Agilent, GBC Scientific, Analytic Jena, Thermo & Unicam.

Photron’s P800C Series for Agilent / GBC Scientific / Varian AAS Instruments compatible with 37mm or 1.5″ base 4 Pin Octal Base, Coded Hollow Cathode Lamps including AAS models such as Agilent 240 AA, 240FS AA, 240Z AA, 280FS AA, 280Z AA, 55B AA, AA Duo, AA3000, AA1275, AA1475, AA275, AA400, AA475, AA775, AA875, AA975 and all GBC Scientific SpectrAA AA’s.

Photron’s P800C Series for Agilent / GBC Scientific / Varian AAS Instruments compatible with 37mm or 1.5″ base 7 Pin Octal Base, Coded Hollow Cathode Lamps including AAS models such as 3300 AAS, 3400 AAS, 3500 AAS, ICE 3300, ICE 3400, ICE 3500.

Photron’s P900 Series for Perkin Elmer AAS Instruments compatible with 51mm or 2″ base 9 Pin, Non-Coded Hollow Cathode Lamps which are designed to suit older Perkin Elmer AAS instruments. If you require lamps to suit Perkin Elmer Instruments that support coding.

Photron’s P900C Series for Perkin Elmer AAS Instruments compatible with 51mm or 2″ base, 12 Pin Plug, Coded Hollow Cathode Lamps which are designed to suit newer Perkin Elmer AAS instruments including SIMAA6000, 5100(PC), 4110ZL, 4100, 4100ZL, 3300, 2100, 1100(B).

Photron’s P900LL Series for Perkin Elmer AAS Instruments compatible with 51mm or 2″ base, 4 Pin Cableless, Coded Hollow Cathode Lamps which are designed to suit Perkin Elmer AAS instruments including PinAAcle 500, PinAAcle 900, AAnalyst 200, AAnalyst 400 AAnalyst 100, AAnalyst 300, AAnalyst 600, AAnalyst 700 and AAnalyst 800 .

Applications – UV-Visible Spectroscopty, Spectrofluorimetry UV detectors attached to HPLC instruments, Colorimetry, Refractometry and as a non-atomic source for background correction in Atomic Absorbtion Spectroscopy.